YZF Pointer Gauges — Mechanical indication with alarm contactsSeries reference image

Oil Level Gauges

YZF Pointer Gauges

Mechanical indication with alarm contacts

A float or telescopic rod drives a pointer through magnetic coupling. High and low oil-level contacts support remote alarms.

Manufacturer: Shenyang Zhiyue Electric Technology Co., Ltd.

Dial diametersØ90 / Ø140 / Ø200 / Ø250 mm
Ambient temperature−45 to +55 °C
Download Datasheet

TECHNICAL DATA

Key specifications

Dial diameters
Ø90 / Ø140 / Ø200 / Ø250 mm
Ambient temperature
−45 to +55 °C
Maximum oil temperature
90 °C
Indication error
Less than 2.5% of full scale
Relative humidity
≤90% at 25 °C
Cable entry
M20 × 1.5
Selected mounting dimensions
Model groupFlange diameterMounting holes
YZF1-9090 mm4 × M8
YZF1/2/3-140140 mm4 × M10
YZF1/2-200; YZF1-250160 mm6 × M10
YZF3-200; YZF2/3-250156 mm6 × M10

Mounting confirmation required: the catalog table lists six holes for 200 / 250 mm models, while some outline drawings show four. Request the exact-model installation drawing before ordering.

MODEL REFERENCES

Select a model for your inquiry.

Listed models and order-code examples identify configurations within this series.

ENGINEERING REVIEW

Technical documents

AVAILABLE NOW · NO FORM REQUIRED

YZF Pointer Gauges Technical Data

Specifications, mounting dimensions and wiring in one PDF.

4 pages · English text / original bilingual drawings · Rev 1.0

Mounting confirmation required: the catalog table lists six holes for 200 / 250 mm models, while some outline drawings show four. Request the exact-model installation drawing before ordering.

Download PDF

Need a configuration-specific drawing or certificate? Send the exact model and requirements.

Transmission lines crossing a mountain landscape

YOUR PROJECT. OUR ATTENTION TO DETAIL.

Tell us what you need.

Send us the model, specifications or an existing nameplate.
We’ll help confirm the configuration for your project.

TRANSFORMER
PROTECTION
COMPONENTS.